ECO-IO range

ECO-IOT

The multi-network measurement card

Pulse meters, tank level, temperature probes: the ECO-IOT collects the boiler room readings and transmits them wirelessly to the ECO-CHES station.

Book a call Features
The ECO-IOT card in its AIDHOM enclosure: water, gas and electricity meters, tank level and up to 30 temperature probes as inputs, wireless link to the ECO-CHES, optional GSM NB-IoT

7

Digital inputs, as pulse counters or ON/OFF.

8

M-Bus meters read by the ECO-IOT.

8 P1 ports

To read smart electricity meters.

Basic configuration

Ten inputs on a single card.

In its basic configuration, the ECO-IOT reads meters, tank level and temperatures, then sends its data wirelessly to the ECO-CHES station.

The ECO-IOT enclosure and its terminal block: 7 digital inputs (water, gas, electricity, alarm…), 1 analogue input for the tank level at 0 – 20 mA, 1 one-wire input for up to 30 temperature probes and 1 P1 port for the digital electricity meter (RJ12 socket); wireless transmission to the ECO-CHES
The ten inputs of the ECO-IOT: 7 digital, 1 analogue, 1 one-wire and 1 P1 port.

7digital inputs

Each one can be configured as a pulse counter or an ON/OFF input.

Pulse meters

A pulse every x kWh or m³: the ECO-IOT records and totals the meter pulses.

ON/OFF inputs

Alarm contact, push button…

1analogue input

Level of a water or heating oil tank, at 0 – 20 mA.

1one-wire input

Up to 30 temperature sensors (boiler flow and return).

1P1 port

Direct reading of the digital electricity meter (RJ12 socket). The ECO-IOT can then be powered by the meter (5 V).

Power supply

220 V mains, M-Bus network (36 V), electricity meter (5 V) or 3.6 V battery (up to 5 years). A backup battery keeps the data for 4 months.

Communication

Wireless with the ECO-CHES station, fitted with the ECO-RF2 card.

Options

One card, several networks.

Depending on the installation, the ECO-IOT connects to the M-Bus, reads several P1 electricity meters and becomes stand-alone with a GSM or WiFi modem.

M-Bus options

M-Bus slave

Sends the pulse meter data read on the inputs over the M-Bus network.

The ECO-CHES M-Bus master module then reads the ECO-IOT directly.

M-Bus mini master

Collects the values of 1 to 4 M-Bus meters.

1 to 4 meters

M-Bus master

Collects the values of 1 to 8 M-Bus meters.

1 to 8 meters

Additional options

GSM modem

The ECO-IOT becomes stand-alone: its data is sent to the ECO-MANAGER platform.

Networks: 4G or NB-IoT · AIDHOM SIM card, 5-year subscription

WiFi modem

The ECO-IOT becomes stand-alone: its data goes through the building’s WiFi network to the ECO-MANAGER platform.

Building’s 2.4 GHz WiFi network · no SIM card

WiFi access point

Access point for 4 ECO-ELEC electricity meters (100 A or 350 A clamps, without opening the circuit).

Example: electric car charging point

Up to 8 digital electricity meters

Direct reading of the digital meter (RJ12 socket); an extension card reads 1 to 7 additional meters.

The ECO-IOT can then be powered by the meter (5 V).

220 V monitoring

Monitors the operation of a device connected to the 220 V mains.

Example: circulation pump, UV lamp, boiler, valve

Data is sent: wirelessly to the ECO-CHES via GSM or WiFi to ECO-MANAGER via M-Bus to the ECO-CHES

Product sheet

ECO-IOT features

  • 7 digital inputs: pulse counters or ON/OFF
  • 1 analogue input, 0 – 20 mA, for a tank level
  • 1 one-wire input to connect up to 30 temperature sensors
  • Up to 8 digital electricity meters and ECO-ELEC meters over WiFi
  • Powered by 220 V, M-Bus, electricity meter or battery
  • IP66 enclosure, for indoor and outdoor use
  • Meter values available on the ECO-MANAGER platform

Dimensions

200 × 120 × 75 mm

Width × height × depth · 990 g · IP66

Networks

RadioM-BusWiFiNB-IoT
Digital inputs
7 (pulses or ON/OFF), response time 50 to 100 µs
Analogue input
1, 0 – 20 mA or 0 – 1 V, 4,096-point resolution (tank level)
One-wire input
Up to 30 temperature sensors, −10 to +70 °C, ±0.5 °C; stainless steel IP65 probes
Electricity meters
Up to 8 digital meters (RJ12, 7 of them via extension card); 4 ECO-ELEC over WiFi
Measurements
24 to 240 per day per meter
Communication
Wireless to the ECO-CHES (868 MHz radio)
M-Bus options
Slave, mini master (1 to 4 meters), master (1 to 8 meters); 2.5 km, 300 to 38,400 bit/s
GSM
GSM modem (4G or NB-IoT), AIDHOM SIM card with 5-year subscription
Other options
220 V monitoring
Power supply
220 V – 3 VA, M-Bus 36 V, electricity meter 5 V or 3.6 V D-type battery (up to 5 years); 4-month backup
Installation
At a height of ± 2 m, more than 50 cm from any metal pipe
Dimensions
200 × 120 × 75 mm
Weight
990 g
Enclosure
Grey halogen-free polycarbonate, IP66, Class II, impact-resistant
Payback
6 to 24 months
Warranty
2 years hardware, 3 years batteries; all-risk cover extendable to 5 years

Works with

ECO-CHESThe boiler room station ECO-RF2The ECO-CHES radio card M-Bus masterReads up to 250 meters ECO-REPExtends the radio network
Previous productECO-RF2 Next productECO-REL-CANRF

Which meters should be read in your boiler room?

We analyse your energy consumption and calculate the return on investment, free of charge.

Choose a date +32 (0)4 377 10 52